Baxter Sigma Spectrum Infusion Pump - Certified Reconditioned
The Baxter Sigma Spectrum Infusion Pump (#35700BAX) includes includes Pole Clamp and Power Adapter.
Warranty: 1 Year - Parts and Labor.
The Baxter Sigma Spectrum Infusion Pump is used for the controlled administration of intravenous fluids. These fluids can include pharmaceutical drugs, blood, blood products, and other compounds of required patient therapy. Intravenous, arterial, subcutaneous, intrathecal, epidural, or irrigation of fluid space are all clinically acceptable intended routes of administration.
Features
Baxter Sigma Spectrum Infusion Pump Features
- Easy to set up and program safely.
- Bright, easy to read color display.
- Can be used with Baxter's standard IV administration sets.
- On-board, digital help screens.
- Quick drug find library search.
- Configurable dose error reduction software.
- Single step titration limit.
- Flow check at start of infusion.
- Secondary container infusion check.
- Bi-directional wireless communication.
- Comprehensive log analysis software to create CQU reports.
Specifications
Baxter Sigma Spectrum Infusion Pump Specifications
-
Dimensions:
-
Standard Battery:
-
Without IV Pole Clamp: 5.8" x 4.2" x 2.5" (147 mm x 107 mm x 63.5 mm).
-
With IV Pole Clamp: 5.8" x 6.4" x 4.7" (147 mm x 163 mm x 119 mm).
-
Wireless Battery Module:
-
Without IV Pole Clamp: 6.3" x 4.2" x 2.5" (160 mm x 107 mm x 63.5 mm).
-
With IV Pole Clamp: 6.3" x 6.4" x 4.7" (160 mm x 163 mm x 119 mm).
-
Weight:
-
Standard Battery:
-
Without IV Pole Clamp: 25 oz +/- 1 oz (708 grams +/- 28 grams).
-
With IV Pole Clamp: 33.5 oz +/- 1 oz (950 grams +/- 28 grams).
-
Wireless Battery Module: Less than or equal to 0.75 lb (340 grams).
-
Battery:
-
Standard Battery:
- Lithium Ion, 1800 mA/h, 7.2V nominal. SIGMA Part Number, 35702.
- Pump operating time on battery power is at least 8 hours at 125 ml/hour with the backlight on (new battery).
- 12 hour recharge time.
- Charging occurs if AC Power Adaptor is plugged in whether pump is ON or OFF.
-
Wireless Battery Module:
- Lithium Ion, 1800 mA/h, 7.2V nominal. SIGMA Part Number, 35083.
- Capacity 4 hrs (500 mL) at 125 mL/hour at the highest backlight settings.
- 12 hour recharge time.
- Charging occurs if AC Power Adaptor is plugged in whether pump is ON or OFF.
-
Pump Characteristics and Flow Rate Accuracy:
- Linear peristaltic mechanism.
- 0.5 to 999 mL/hour flow range in 0.1 mL/hour increments from 0.5 to 99.9 mL/hour and 1 mL/hour increments thereafter.
- Volumetric accuracy (based on volume collected over one hour) using standard Hospira, Baxter.
- +/- 5% from 2 to 800 mL/hour, greater than 800 mL/hour +/- 1-% for Hospira +/- 5% from 2 to 999 mL/hour for Baxter, 0.5 to 1.9 m/hour +/-0.1 mL. Total volume up to 9 liters (Hospira) or 12 liters (Baxter).
- KVO - Keep vein open rate of either 1 mL/hour or the actual rate, whichever is lower, at infusion complete alarm.
- Maximum pump pressure - 36 PSI (which can never be obtained with operational occlusion alarm limits).
-
Wireless Network Interface:
-
Standard: IEEE 802.11b.
-
Frequency: 2.4 GHz.
-
Data Rate: Up to 11 Mbps with automatic fallback.
-
Modulation: CCK (11/5 Mbps), DQPSK (2 MBPS), DBPSK (1 MBPS).
-
Transmit Power: 16 dBm typical.
-
Receiver Sensitivity: -82 dBm at 11 Mbps.
-
Wireless Security:
-
WEP (Wired Equivalent Privacy): 64/128-bit encryption (RC4).
-
WPA/WPA2/802.11i:
- 128-bit TKIP/CCMP encryption.
- 802.1 x EAP authentication:
- LEAP (WEP only), PEAP, TTLS.
- GTC, MD5, OTP, PAP, CHAP, MSCHAP, MSCHAPc2, TTLS-MSCHAPv2.
- Pre-shared key mode (PSK).
-
Environmental Limits:
-
With Standard Battery:
-
Operating Temperature: 60 to 90 degrees F (15.6 to 32.3 degrees C), 20 to 90% relative humidity non-condensing.
-
Storage Temperature: -4 to 120 degrees F (-20 to 49 degrees C), 10 to 90% relative humidity non-condensing.
-
With Wireless Battery Module:
-
Operating Temperature: 60 to 80 degrees F (15.6 to 26.7 degrees C), 20 to 90% relative humidity non-condensing.
-
Storage Temperature: -4 to 120 degrees F (-20 to 49 degrees C), 10 to 90% relative humidity non-condensing.
-
Display: Full color, HRTFT, 240 x 270, LED front-lit, 0.2235 mm x 0.2235 mm dot pitch.
-
Alarms and Alerts:
-
Air-In-Line: Dual beam ultrasonic detector alarms for large bubbles but allows smaller bubbles to pass. Detects air bubbles greater than 1" (≈ 125μL Hospira, ≈ 140μL Baxter), will alarm if greater than 1 mL of air in 15 min., less than 50μL bubbles are omitted in the summation of the 1 mL.
-
Audio: Speaker actuated audio alarm, low, medium, and high levels selected through the configurations screen.
-
Battery Missing: Pump does not detect battery attached.
-
Depleted Battery: Pump stops running, alarms for 3 minutes.
-
Dose Rate Limit Exceeded: The pump will run with a soft dose rate exceeded after a double confirmation, it will not run with a hard dose rate exceeded, rates must be reset within hard limits.
-
Downstream Occlusion: Automatic restart occurs after the downstream occlusion is cleared. Actuation can be set to Low, 6 +/- 4 PSI, Medium, 13 +/- 6 PSI, or High, 19 +/- 9 PSI.
-
Inactivity: Actuates after the pump has been inactive for 2 minutes.
-
Infusion Complete: Occurs when the VTBI reaches zero, at which time a KVO rate begins (the previous running rate or 1 mL/hour, whichever is lower).
-
In Stop: Load set.
-
In Stop: Open side clamp.
-
In Stop: Push run.
-
Low Battery: Less than 30 minutes of battery power remain.
- Shut Door.
-
Side Clamp Closed: Pump stopped.
- System Error.
- Upstream Occlusion.
-
Very Low Battery: Less than 15 minutes of battery power remain.
-
Timekeeping: Real time clock, battery backed, 10 year life.
-
Logging Memory:
- 24 hour memory of all set up screens except for ramp/taper modes that are maintained permanently.
- Separate pump and drug library history logs, minimum of 96 hours each under extensive logging intensive operating conditions.
-
AC Power:
- AC Power Adaptor, low profile, covers only one outlet, Medical Grade (EN60601-1-2), Input: 100 V-AC-240V-AC, 50 to 60 Hz/200 mA, Output: 9V-DC/800mA, short circuit protected, cord length 3.0 m (~ 9.75'). Use only SIGMA part number 55079 or equivalent.
- The SIGMA Spectrum Infusion Pump is classified according to Medical Electrical Equipment standards as:
- Class II Equipment.
- Type BF Applied Part.
- Continuous Operation.
-
External Interfaces: RS-232 (RTX and CTS only), IrDA (SIR Encoding Protocol. Supports IrOBEX). Additional Asynchronous Serial Port Expansion bus available at battery terminals. Software upgrades may be performed through external RS-232 or IrDA ports.
-
Standards:
- IEC60601-1 including collateral standards; Third Party Notified Body Testing (Reference Electromagnetic Compatibility Tables).
- IrDA Serial Infrared Physical Layer Link Specification v1.4(IrPHY), IrDA Serial Infrared Link Access Protocol v1.1 (IrLAP) and IrDA Serial Infrared Link Management Protocol v1.1 (IrLMP), IrDA Tiny TP v1.1.
- Wireless - 802.11b.
- EIA-RS-232 levels for Asynchronous Transmit/Receive only (RS232).
Literature
Baxter Sigma Spectrum Infusion Pump Literature
Baxter 35700BAX and 35700ABB Sigma Spectrum Infusion Pump Operator's Manual