The reconditioned OEC 9900 Elite select configurations are ideal for Office,Outpatient and Ambulatory Center settings.
Superb Imaging
• 1k x 1k x 16 bit resolution imaging
• Advanced image processing accentuates what needs to be seen and attenuates what isn’t needed
• Dynamic Range Management technology processes images such as bone and vasculature separately for optimum definition
• Dose management options for more control: Digital Spot,High Level Fluoroscopy, Standard Fluoroscopy, Low Dose, and Pulse Mode
• Smart Metal for enhanced imaging when metal is present
• AutoTrak sampling window automatically moves with the anatomy to ensure superb images during live fluoro
Workflow Efficiency
• Simple user interface with touchscreen reduces procedure time to improve efficiency
• Flat panel monitors on an articulating arm allow viewing of images from anywhere in the room
• Superb mechanical C-arm design features counterbalancing and friction controls for easier AP and lateral movement, orbital rotation, and head-to-toe angulation
Refurbishing Process:
All OEC-9800’s go through a multistep refurbishing process. Each unit is restored to a like-new status. Pain Management, Orthopedics and Rehabilitation Services are just a few of the applications utilizing the reconditioned OEC-9800 c-arm. The rotating x-ray tube allows for greater penetration and resolution for the lumbar area when doing needle localizations or other work involving the thicker anatomical areas of patients. For barium swallows a VCR or Digital Video Recorder can be utilized for better record keeping and post study analysis. The 1K X 1K CCD Technology used in the OEC-9800 image system allows for crisp, clear imaging. Whatever the purpose, a reconditioned OEC-9800 will deliver the results you can depend on.
Mechanical repairs/cosmetic maintenance
• All defective parts and covers are repaired or replaced
• C-arm is completely disassembled and repainted
• “C” is removed from main frame assembly
• Horizontal arm removed, inspected and repaired as necessary
• Vertical column removed and bearings removed inspected and replaced as required
• X-ray tube removed and inspected for artifacts and internal integrity
• Image intensifier removed and inspected for any imperfections and grid integrity
• Camera removed
• Wheels removed, cleaned and or replaced from main chassis
• Chassis inspected for structural defects and repaired as necessary
• Vertical lift assembly is tested for drift and adjusted/replaced if necessary
• All bearings are inspected, cleaned and re-lubricated, or replaced as needed
• Control panel display is tested and replaced if necessary
• All wheels are inspected and lubricated and/or replaced as needed, with new cable pushers installed
• All locks and brake assemblies are inspected, cleaned, and repaired or replaced as needed
• C-arm is completely disassembled and repainted
• Steering is tested and adjusted is required
• Foot switch and hand switch provided on each unit
• A complete set of operator and service manuals are provided
Re-assembly
• All components sent to C-arm reassembly area for rebuilding
• “C”, Image tube and camera, Vertical column, main control and power cable installed
• New batteries are installed
• New CRT monitors installed in monitor cart
• Monitor cart rebuilt
• When C-arm is completely rebuilt mechanically system is sent for calibration and final testing
Testing/calibration
• Image intensifier and X-ray tube are tested for stability and balance
• Image intensifier is tested for resolution and gain to be within OEM specifications
• X-ray tube bearings are tested for noise and coast time
• X-ray tube filaments and stator windings are tested
• X-ray tube radiation output is verified to be within OEM specifications
• X-ray generator high voltage tested
• Maximum dose rate is set in compliance with government regulations
• CCD camera calibrated to OEM specifications
• X-ray beam is aligned for each field size
• C-arm is tested for current leakage requirements
• All monitors are aligned, resized, centered and focused
• All monitors are adjusted for brightness and linearity
• Video system is optimized for gray scale and resolution
• All power supplies are tested and calibrated or replaced as necessary
Specifications |
X-ray System Generator
• 0.3 and 0.6 nominal focal spots
Fluoro Mode Pulsed Fluoro Mode High Level Pulsed Fluoro Digital Spot Mode Video Imaging System 9” Image Intensifier
AutoTrak Automatic Brightness Stabilization (ABS) Image Quality Features • 1200 CD/M2 maximum brightness Software Package Office Pain (OP) and Ambulatory Center (AC)
Additional Features • Multi-functional controls Uninterruptible Power
|
---|---|